RS485 Modbus Class 0.5S Panel Mounted Multi-function Power Analyzer

  • RS485 Modbus Class 0.5S Panel Mounted Multi-function Power Analyzer
  • RS485 Modbus Class 0.5S Panel Mounted Multi-function Power Analyzer
  • RS485 Modbus Class 0.5S Panel Mounted Multi-function Power Analyzer
  • RS485 Modbus Class 0.5S Panel Mounted Multi-function Power Analyzer
  • RS485 Modbus Class 0.5S Panel Mounted Multi-function Power Analyzer
  • RS485 Modbus Class 0.5S Panel Mounted Multi-function Power Analyzer

Smart X96-5S

RS485 Modbus Class 0.5S Panel Mounted Multi-function Power Analyzer

  • Multi-parameters measurement
  • Up to 63rd THD
  • RS485 Modbus RTU
  • High accuracy of Class 0.5S
  • SOE recording
  • Waveform logging
  • TOU (Time-of-Use)
  • Digital input and digital output

Eastron Smart X96-5S is a new generation panel mounted multi-function power analyzer, serving as a digital monitoring terminal and an intelligent device integrating measurement, monitoring, and communication. It utilizes modern computer and digital signal processing technology, enabling it to replace various transmitters, meters, relays, and other components. The multi-function power analyzer features an RS-485 interface and supports the standard MODBUS-RTU communication protocol, allowing seamless integration into any power monitoring system.

Eastron Smart X96-5S is designed for power monitoring applications in power systems, industrial and mining enterprises, public facilities, and smart buildings. It measures all common electrical parameters, such as three-phase current, voltage, active and reactive power, and energy consumption, making it highly suitable for real-time power monitoring systems.

With an excellent performance-to-price ratio, the Smart X96-5S can directly replace conventional power transmitters and measurement instruments. As an advanced intelligent and digital front-end acquisition component, it is widely applicable in various control systems, SCADA systems, and energy management systems.

Electrical characteristics

Type of measurement

RMS including harmonics on three phase AC system (3P, 3P+N)

Measurement accuracy

Active power

±1%

Reactive power

±1%

Apparent power

±1%

Active Energy

Class 0.5S IEC 62053-22

Class C EN50470-3:2022

Reactive Energy

Class 2 IEC 62053-23

Frequency

±0.2%

Current

±0.2%

Voltage

±0.2%

Power Factor

±0.01

 

Input & Output

Input

Current

Rated Current

5A

Max Current

6A

Min Current

0.05A

Starting Current

50mA

Voltage

Aux. power supply

100~480V AC / 141~678V DC

Measured voltage

50V ~ 600V AC (L-L)

50V ~345V AC (L-N)

Communication

Interface 1

RS485

Protocol

Modbus-RTU

Baud rate

2400bps ~ 115200 bps, default: 9600 bps

Address

1 to 247

Pariy

None (default), Even, Odd

Stop Bit

1 or 2

Interface 2

Ethernet

Protocol

Modbus-TCP

IP

192.168.1.200 (default)

Port

502

Mask

255.255.255.0

Gateway

192.168.1.1

DHCP

OFF (default)

 

Mechanical Characteristics

Weight

322g

IP Degree of Protection (IEC 60529)

IP51 front display

Dimensions (WxHxD)

96x96X73.5 mm

Panel cut-out

Vertical

Material of meter case

Self-extinguishing UL 94 V-0

 

Environmental Characteristics

Operating Temperature

-25 to 75°C

Storage Temperature

-40 to  85°C

Humidity Rating

<95% RH (non-condensing)

Pollution Degree

2

Altitude

2000m

Wiring and Dimension [mm:]

Installation and Dimension [mm:]

Installation

Installation and Dimension [mm:]