Residual Current Operated Protective Sensor for EV Charger

  • Residual Current Operated Protective Sensor for EV Charger
  • Residual Current Operated Protective Sensor for EV Charger
  • Residual Current Operated Protective Sensor for EV Charger
  • Residual Current Operated Protective Sensor for EV Charger
  • Residual Current Operated Protective Sensor for EV Charger
  • Residual Current Operated Protective Sensor for EV Charger
  • Residual Current Operated Protective Sensor for EV Charger
  • Residual Current Operated Protective Sensor for EV Charger

ESCS-G1-E1/E3

Residual Current Operated Protective Sensor for EV Charger

  • DC 6mA Current Alarm
  • Mounted on PCB Board
  • Integrated Digital Residual Current Indication
  • Application for EV Charger

ESCS-G1 is residual current operated protective sensor for EV charger.

It's to avoid hazardous situations in cases where the vehicle battery (DC) is connected to the home power supply (AC). Generally, AC/DC sensitive residual current sensors can be used where direct current and alternating current circuits are directly connected and therefore AC/DC leakage currents can occur.

It meets the standards of IEC 62752, IEC 62955 RDC-PD related residual current operating characteristics requirements and GB/T 22794 basic residual current operating characteristics requirements, adapting to DC 6mA test requirements.

Product Features:

●Type-A+6mA residual current module for EV charging pile protection

●All-in-One highly integrated digital residual current action indication

●Integrated with self-test and calibration functions , saving hadware resources

●Primary conductors on module 40A RMS

●High level of safety, providing a way of effectively identificating of failures*

●Residual current value reported , achieving refined management*

International Standards:

●IEC 62955-2018 residual current requirements for RDC-PD

●GB/T 22794 basic residual current requirements , adapting to DC 6mA test requirements

Clearance

Primary-Primary

 ≥ 8.2mm

Primary-Secondary

 ≥ 5.8mm

 

Creepage

Primary-Primary

 ≥ 8.2mm

Primary-Secondary

 ≥ 5.8mm

 

Environment

Operating Temperature

 -40℃… +105℃

Storage Temperature

 -40℃…+105℃

Humidity

 ≤95% non-condensing

FIT

 25℃= 48.755, 80℃= 213.13

MTBF

 ≥ 20 years

Altitude

 ≤ 4000m

 

Order code

Current Input

Digital Input

Digital Input

Standard

ESCS-G1-E1

DC 6mA/ AC 30mA

0V/5V

/

IEC62955 RDC-PD

ESCS-G1-E3

DC 6mA/ AC 30mA

0V/5V

IEC62955 RDC-PD

 

Wiring and Dimension [mm:]