Need Help? - Call: 0086-573-8369881/8369882 or email: sales@eastrongroup.com

中文版English

  • SDM630MV-CT 333mV CT Operated 3P3W/3P4W/1P2W Mutlifunction Power Analyser WithRS485 Port modbus RTU and Pulse Outputs

    • Measures kWh Kvarh, KW, Kvar, KVA, P, F, PF, Hz, dmd, V, A, THD,etc.
    • Bi-directional measurement IMP & EXP
    • Two pulse outputs
    • RS485 Port modbus RTU
    • Din rail Mounted
    • 0.33V CT connection
    • Class 1.0 accuracy
    • 72mm 4 modual width
    • Description
    • Diagram
    • Manual Download
    Introduction
    The unit measures and displays the characteristics of three phase four wires(3p4w) supplies, including voltage, frequency, current, power ,active and reactive energy, imported or exported. Energy is measured in terms of kWh, kVArh. Maximum demand current can be measured over preset periods of up to 60minutes. In order to measure energy, the unit requires voltage and current inputs in addition to the supply required to power the product. The requisite current input(s) are obtained via current transformers(CT).

    This meter can be configured to work with a wide range of CTs with 0.33V output, giving the unit a wide range of operation. Built-in interfaces provides pulse and RS485 Modbus RTU outputs. Configuration is password protected.

    This unit can be powered from a separate auxiliary(AC or DC)supply. Alternatively it can be powered from the monitored supply, where appropriate.

    Unit Characteristics
    The Unit can measure and display:
    Line voltage and THD% (total harmonic distortion) of all phases
    Line Frequency
    Currents, Current demands and current THD% of all phases
    Power, maximum power demand and power factor
    Active energy imported and exported
    Reactive energy imported and exported

    The unit has password-protected set-up screens for:
    Changing password
    Demand Interval time
    Reset for demand measurements
    Pulse output duration 

    Two pulse output indicates real-time energy measurement. An RS485 output allows remote monitoring from another display or a computer.

    Current Transformer Primary Current
    The unit can be configured to operate with CT with 0.33V output. The secondary CT is fixed 0.33V, and the primary is optional.

    RS485 Serial – Modbus RTU
    This uses an RS485 serial port with Modbus RTU protocol to provide a means of remotely monitoring and controlling the Unit.
    SDM630MV-CT provides two pulse outputs that clock up measured active and reactive energy. The constant for reactive energy is 3200imp/kVArh. The pulse width for active energy can be set from the set-up menu.