  • SDM320A 100A 230V Single Phase Two Wires kWh Meter

    • Measure active energy
    • Analog display
    • pulse output
    • Din rail Mounted
    • 100A direct connection
    • Class 1.0 accuracy
    • 76mm width 4 modual
    • Description
    • Diagram
    • Manual Download

    Application


    The SDM220D “with a LCD screen for prefect reading”, SDM220A with an electromechanical register, are used to measure single-phase like residential, utility and Industrial application. The meter measures active energy meter (kWh) with a pulse output. 

    General Specifications
    Voltage AC (Un) 230V
    Voltage Range  176~276V AC
    Base Current (Ib)   10A
    Max. Current (Imax) 80A
    Mini Current (Imin)  0.5A
    Starting current  0.4% of Ib
    Power consumption  <2W/10VA
    Frequency   50/60Hz(±10%)
    AC voltage withstand  4KV for 1 minute
    Impulse voltage withstand  6KV-1.2uS wavform
    Overcurrent withstand  30Imax for 0.01s
    Pulse output rate  1000imp/kWh (default)
    Display  SDM220D LCD (backlit optional)
    SDM220A electromechanical register
    Max. Reading  99999.9kWh
    Voltage 0.5% of range maximum
    Current 0.5% of nominal
    Frequency   0.2% of mid-frequency
    Power factor 1% of Unity
    Active power   1% of range maximum
    Reactive power   1% of range maximum
    Apparent power  1% of range maximum
    Active energy  Class 1 IEC62053-21
    Class B EN50470-3
    Reactive energy  1% of range maximum
    Environment 
    Operating temperature   -25℃ to + 55℃
    Storage and transportation temperature  -40℃ to +70℃
    Reference temperature 23℃±2℃
    Relative humidity   0 to 95%, non-condensing
    Altitude  up to 2500m
    Warm up time  10s
    Mechanical Environment M1
    Electromagnetic environment E2
    Degree of pollution  2

    Pulse Output

    The meter provides a pulse output, which is passive type. The constant is 1000imp/kWh.

    ATTENTION: Pulse output must be fed as shown in the wring diagram below. Scrupulously respect polarities and the connection mode.

    Opt0-coupler with potential-free SPST-NO Contact

    Contact range: 5~27VDC  Max. current Input: 27mA DC

    Mechanics
    Din rail dimensions   36x90x62 (WxHxD) DIN 43880
    Mounting  DIN rail 35mm
    Sealing   IP51 (indoor)
    Material Self-extinguishing UL94V-0




    Introduction

    The Eastron SDM320D/A DIN rail single phase two wire energy meter with S0 pulse output. SDM320D has LCD display, and SDM320A has analog display, based on kWh. The meter is provided with a non-volatile memory system that ensures that the readings are not lost or altered when power off. The meter allows up to 100A direct load in single phase application. It is perfect measuring instruments for AMR system or Energy monitoring and control system.



    General Specifications
    Voltage AC (Un) 230V
    Voltage Range  176~276V AC
    Base Current (Ib)   10A
    Max. Current (Imax) 100A
    Mini Current (Imin)  0.5A
    Starting current  0.4% of Ib
    Power consumption  <2W/10VA
    Frequency   50/60Hz(±10%)
    AC voltage withstand  4KV for 1 minute
    Impulse voltage withstand  6KV-1.2uS wavform
    Overcurrent withstand  30Imax for 0.01s
    Pulse output rate 

    1600imp/kWh

    Display  SDM220D LCD (backlit optional)
    SDM220A electromechanical register
    Max. Reading  99999.9kWh
    Voltage 0.5% of range maximum
    Current 0.5% of nominal
    Frequency   0.2% of mid-frequency
    Power factor 1% of Unity
    Active power   1% of range maximum
    Reactive power   1% of range maximum
    Apparent power  1% of range maximum
    Active energy  Class 1 IEC62053-21
    Class B EN50470-3
    Reactive energy  1% of range maximum
    Environment 
    Operating temperature   -25℃ to + 55℃
    Storage and transportation temperature  -40℃ to +70℃
    Reference temperature 23℃±2℃
    Relative humidity   0 to 95%, non-condensing
    Altitude  up to 2500m
    Warm up time  10s
    Mechanical Environment M1
    Electromagnetic environment E2
    Degree of pollution  2

    Pulse output

    The SDM320D/A DIN rail energy meter is equipped with a pulse output which is fully separated from the inside circuit. That generates pulses in proportion to the measured energy for accuracy testing. 

    The pulse output is a polarity dependant, passive transistor output requiring an external voltage source for correct operation. For this external voltage source, the voltage (Ui) should is 5-27V DC, and the maximum input current (Imax) is 27mA DC. To connect the impulse output, connect 5-27V DC to connector 6 (anode), and the signal wire (S) to connector 5 (cathode). The meter pulses is indicated on the front panel.