Need Help? - Call: 0086-573-8369881/8369882 or email: sales@eastrongroup.com

中文版English

  • SDM230-DR MID Certificated 100A Single Phase Energy Meter Partial Energy Resettable

    • Measure active energy + Power
    • Resettable partial energy
    • Two pulse outputs
    • Din rail Mounted
    • 100A direct connection
    • Class 1.0 accuracy
    • 36mm width 2 modual
    • Description
    • Diagram
    • Manual Download

    Application

    The energy-meters “with a blue back-lighted LCD screen for prefect reading” are used to measure single-phase like residential, Utility and Industrial application. The unit measures and displays various important electrical parameters. 

    There are two buttons on the front panel, one is used for scroll the info pages, another to reset partial energy information.

    General Specifications
    Voltage AC (Un) 230V
    Voltage Range  176~276V AC
    Base Current (Ib)   10A
    Max. Current (Imax) 100A
    Mini Current (Imin)  0.5A
    Starting current  0.4% of Ib
    Power consumption  <2W/10VA
    Frequency   50/60Hz(±10%)
    AC voltage withstand  4KV for 1 minute
    Impulse voltage withstand  6KV-1.2uS wavform
    Overcurrent withstand  30Imax for 0.01s
    Pulse output rate  1000imp/kWh (Import)
    1000imp/kWh (Export)
    Display  LCD with blue backlit
    Max. Reading  99999.9kWh
    Accuracy
    Voltage 0.5% of range maximum
    Current 0.5% of nominal
    Frequency   0.2% of mid-frequency
    Power factor 1% of Unity
    Active power   1% of range maximum
    Reactive power   1% of range maximum
    Apparent power  1% of range maximum
    Active energy  Class 1 IEC62053-21
    Class B EN50470-3
    Reactive energy  1% of range maximum
    Environment 
    Operating temperature   -25℃ to + 55℃
    Storage and transportation temperature  -40℃ to +70℃
    Reference temperature 23℃±2℃
    Relative humidity   0 to 95%, non-condensing
    Altitude  up to 2500m
    Warm up time  10s
    Mechanical Environment M1
    Electromagnetic environment E2
    Degree of pollution  2

    Output



    Pulse Output

    The meter provides two pulse outputs. Both pulse outputs are passive type.

    Pulse 1Export active energy, constant 1000imp/KWh, pulse width 100ms, non-configurable

    Pulse 2Import active energy, constant 1000imp/KWh, pulse width 100ms, non-configurable


    Mechanics

    Din rail dimensions  

    36x99x63 (WxHxD) DIN 43880
    Mounting  DIN rail 35mm
    Sealing   IP51 (indoor)
    Material Self-extinguishing UL94V-0