Need Help? - Call: 0086-573-8369881/8369882 or email: sales@eastrongroup.com

中文版English

  • SMART X96-5 Multi-function Panel Mounted Power Analyzer, Easy Wiring, RS485 Modbus, 1A or 5A

    Measures kWh, kVarh, kW, kVar, kVA, P, F, PF, Hz, dmd, V, A, etc.

    Bi-directional Measurement IMP & EXP
    Energy Information of Each Phase
    Two Pulse Outputs
    RS485 Modbus RTU
    Total Harmonic Distortion of Voltage and Current
    2nd~63rd Individual Harmonic Distortion
    Backlit LCD Display for Full Viewing Angles
    Class 1 , Class 0.5S
    Bar Graph for Power Indication
    Dimension 96x96mm
    1A/5A CT connection



    • Description
    • Diagram
    • Manual Download

    Introduction

    The multifunction energy analyzer SMART X96 series is a top new-generation intelligent panel meter, used not only in the electricity transmission and power distribution system, but also in the power consumption measurement and analysis in high voltage intelligent power grid.
    The unit measures and displays the characteristics of single phase two wires, three phase three wires and three phase four wires supplies, including voltage, frequency, current, power and active and reactive energy, imported or exported, Harmonic, Power factor, Max. Demand etc. Energy is measured in terms of kWh, kVArh. Maximum demand current can be measured over preset periods of up to 60minutes. In order to measure energy, the unit requires voltage and current inputs in addition to the supply required to power the product. The requisite current input(s) are obtained via current transformers The SMART X96 can be configured to work with a wide range of CTs, giving the unit a wide range of operation. Built-in interfaces provide pulse and RS485 Modbus RTU outputs. Configuration is password protected. 


    Unit Characteristics
    Line voltage and THD% (total harmonic distortion) of all phases
    2~63rd voltage IHD% (Individual Harmonic distortion) of all phases
    Line Frequency
    Currents, Current demands and current THD% of all phases
    2~63rd current IHD% of all phases
    Active power, reactive power, apparent power, maximum power demand and power factor
    Active energy imported and exported
    Reactive energy imported and exported
    Energy of each phase

    The unit has password-protected set-up screens for:
    Communication setting: Modbus address, Baud rate, Parity, Stop bit
    CT setting: CT 1 ( Primary) , CT2 ( Secondary), CT rate
    PT setting: PT1 (Primary), PT2 (Secondary) , PT rate
    Pulse setting: Pulse output 1, Pulse rate, Pulse time
    Demand setting: Demand interval time, demand method
    Time setting: Backlit time, display scroll time
    System configuration: System type, System connect, Change password, Auto display scroll
    Reset
     
    CT and PT

    CT1 (primary current):5~9999A
    CT2 (secondary current): 1A or 5A
    PT1 (primary voltage): 100V ~ 500,000V
    PT2 (secondary voltage): 100 to 480 V AC (L-L)

    RS485 Serial–Modbus RTU
    This unit uses a RS485 serial port with Modbus RTU protocol to provide a means of remote monitoring and controlling. Please check the Part 4.2 for the details of setting.


    Pulse output

    Two pulse outputs indicate real-time energy measurement. Pulse output 1 is configurable, pulse output 2 is fixed to active energy, 3200imp/kWh.